YIN Gang (Xi’an Jiaotong University. CAUSE ANALYSIS OF FREQUENT BURST-LEAKAGE OCCURRED ON REHEATER AND WATER-WALL OF 300 MW UTILITY BOILER[J]. Thermal power generation, 2007, (3): 32-34.
DOI:
YIN Gang (Xi’an Jiaotong University. CAUSE ANALYSIS OF FREQUENT BURST-LEAKAGE OCCURRED ON REHEATER AND WATER-WALL OF 300 MW UTILITY BOILER[J]. Thermal power generation, 2007, (3): 32-34. DOI: 10.19666/j.rlfd.2007.03.009.
CAUSE ANALYSIS OF FREQUENT BURST-LEAKAGE OCCURRED ON REHEATER AND WATER-WALL OF 300 MW UTILITY BOILER
Directing against the troubles of frequent burst-leakage occurred in recent years on water-wall and platen reheater of boilers in one power plant
the main causes resulting in burst-leakage have been analysed. It is believed from analysis that the burst-leakage of platen reheater is mainly due to high-temperature oxidation failure resulted from over-temperature. Through adopting measures in operation
such as controlling the fineness of pulverized coal
heigtening the grade of tube material
applying spray coatings on outer surface of tubes for preventing high-temperature oxidation etc.
the number of occurred burst-leakage troubles has been reduced. The thickness-reducing of water-wall tubes is due to high-temperature corrosion