HYDRODYNAMIC CALCULATION OF 600 MW SUPERCRITICAL CFB BOILER
the hydrodynamic calculation of water - wall tubes in 600 MW supercritical circulating fluidised bed (CFB) boiler adopting four kinds of once - through up - flow tube
namely austenitic steel smooth tube
carbon steel smooth tube
four - thread refled tube
and single - thread refled tube
has been carried out Results show that : (1) decreasing the frictional resistance coefficient of water - wall tubes can slow down the beat deviation
and decrease the total preasure drop ; (2) Along with increasing the distance deviated from center tube
the heat deviation of four kinds for water - wall tubes all to be lowered
the frictional pressure drop and the acceleration pressure drop also to be gradually lowered
but the weight pressure drop to be gradually increased; (3) along with incressing the distance deviated from center tube
the varying tendency of flow rate deviation for austenitic steel smooth tube to be gradually lowered * the flow rate deviation of carbon steel smooth tube to be increased first
find to be lowered later
but the flow rate deviation of four-thread and signle - thread rifled tubes all to be gradually increased.