ZHANG Min-qi, XUE Jia-lin, GAO Shang-de. CAUSE ANALYSIS AND COUNTERMEASURES FOR BURST-CRACKING OF PLATEN SUPERHEATER OF BOILER NO.1[J]. Thermal power generation, 2006, (8): 69-70.
DOI:
ZHANG Min-qi, XUE Jia-lin, GAO Shang-de. CAUSE ANALYSIS AND COUNTERMEASURES FOR BURST-CRACKING OF PLATEN SUPERHEATER OF BOILER NO.1[J]. Thermal power generation, 2006, (8): 69-70. DOI: 10.19666/j.rlfd.2006.08.026.
CAUSE ANALYSIS AND COUNTERMEASURES FOR BURST-CRACKING OF PLATEN SUPERHEATER OF BOILER NO.1
摘要
通过对1号炉屏式过热器爆管管样的宏观检验、壁厚测量和金相检验
对爆管原因进行了分析。结果表明:爆管主要是由于管子长期过热所致
而屏式过热器管卡烧损、个别管段出列、减温水调节方式不当是引起屏式过热器超温的主要原因。
Abstract
Through macroscopic examination
wall-thickness measurement
and metallographic examination of tube specimen taken from the bursted platen superheater of boiler no.1
the causes leading to tube-burst have been analysed. Results show that the tube-burst is mainly due to the result of tube’s long term overheating
while the main causes resultsing in overtemperature of the platen superheater are as follows: (1) burn-out of superheater’s pipe-grippers; (2) some tube-sections are out of the row; (3) unsuitable mode for adjusting the desuperheating water.