CHEN Qing-hui. ANALYSIS ABOUT ECONOMIC BEHAVIOR IN OPERATION OF HIGH-PRESSURE HEATER FOR 300 MW UNIT[J]. Thermal power generation, 2006, (8): 38-41.
DOI:
CHEN Qing-hui. ANALYSIS ABOUT ECONOMIC BEHAVIOR IN OPERATION OF HIGH-PRESSURE HEATER FOR 300 MW UNIT[J]. Thermal power generation, 2006, (8): 38-41. DOI: 10.19666/j.rlfd.2006.08.013.
ANALYSIS ABOUT ECONOMIC BEHAVIOR IN OPERATION OF HIGH-PRESSURE HEATER FOR 300 MW UNIT
摘要
分析湛江电力有限公司3、4号机组高压加热器(高加)系统运行中出现的异常现象
查明了高加发生故障的原因
提出了改进措施
并通过试验
确定了高加系统的经济运行方式。
Abstract
The abnormal phenomena appeared in operation of high-pressure heater system for unit no.3 and no.4 in Zhanjiang Power Co Ltd have been analysed
the causes leading to high-pressure heater failure being found out
and retrofitting measures being put forward. Through test
the economic operation mode of the high-pressure heater system has also been determined.