LI Jie, TIAN Wen-zeng. ANALYSIS AND REMEDY OF VALVE STEM LEAKAGE FOR HIGH-PRESSURE MAIN STEAM VALVE OF 300 MW UNIT[J]. Thermal power generation, 2006, (8): 36-37.
DOI:
LI Jie, TIAN Wen-zeng. ANALYSIS AND REMEDY OF VALVE STEM LEAKAGE FOR HIGH-PRESSURE MAIN STEAM VALVE OF 300 MW UNIT[J]. Thermal power generation, 2006, (8): 36-37. DOI: 10.19666/j.rlfd.2006.08.012.
ANALYSIS AND REMEDY OF VALVE STEM LEAKAGE FOR HIGH-PRESSURE MAIN STEAM VALVE OF 300 MW UNIT
摘要
对德州电厂1号汽轮机组在经过DEH控制系统改造后高压主汽门杆发生蒸汽泄漏的原因进行了分析
认为蒸汽泄漏是热态时阀门开度不足所致。通过调整热控参数
消除了热态时阀门开度不足问题
主汽门杆再未发生蒸汽泄漏。
Abstract
After retrofitting the digital electro-hydraulic (DEH) Control System of the steam turbine unit no.1 in Dezhou Power Plant
the valve stem leakage has occurred on the highpressure main steam valve
and the causes leading to the said leakage being analysed. Through adjustment of the thermal control parameters
the valve stem leakage problem of the main steam valve resulted from insufficient opening in hot state has been eliminated.