MA Wang-peng. ANALYSIS OF UNUSUAL TEMPERATURE VARIATION CONCERNING MEDIUM-PRESSURE CYLINDER IN START-UP PROCESS OF 330 MW UNIT MADE BY ROMANIA[J]. Thermal power generation, 2006, (8): 33-35.
DOI:
MA Wang-peng. ANALYSIS OF UNUSUAL TEMPERATURE VARIATION CONCERNING MEDIUM-PRESSURE CYLINDER IN START-UP PROCESS OF 330 MW UNIT MADE BY ROMANIA[J]. Thermal power generation, 2006, (8): 33-35. DOI: 10.19666/j.rlfd.2006.08.011.
ANALYSIS OF UNUSUAL TEMPERATURE VARIATION CONCERNING MEDIUM-PRESSURE CYLINDER IN START-UP PROCESS OF 330 MW UNIT MADE BY ROMANIA
摘要
华电蒲城发电有限责任公司2台罗马尼亚330MW机组在起动过程中出现了中压缸温度异常变化情况
分析了缸温异常变化带来的危害
总结了引起汽缸温度异常变化的原因
提出了相应的防范措施。
Abstract
For two 330 MW units made by Romania and installed in Huadian Pucheng Power Generating Co Ltd
unusual temperature variation concerning medium-pressure cylinder has occurred in start-up process of said units. The harmfulness resulting from unusual variation of cylinder temperature has been analysed
and the causes leading to unusual variation of cylinder temperature being summarized
and then corresponding preventive measures being put forward.