ANALYSIS OF UNUSUAL TEMPERATURE VARIATION CONCERNING MEDIUM-PRESSURE CYLINDER IN START-UP PROCESS OF 330 MW UNIT MADE BY ROMANIA
更新时间:2025-09-28
    • ANALYSIS OF UNUSUAL TEMPERATURE VARIATION CONCERNING MEDIUM-PRESSURE CYLINDER IN START-UP PROCESS OF 330 MW UNIT MADE BY ROMANIA

    • Thermal Power Generation   Issue 8, Pages: 33-35(2006)
    • DOI:10.19666/j.rlfd.2006.08.011    

      CLC: TM621.3
    • Published:2006

    移动端阅览

  • MA Wang-peng. ANALYSIS OF UNUSUAL TEMPERATURE VARIATION CONCERNING MEDIUM-PRESSURE CYLINDER IN START-UP PROCESS OF 330 MW UNIT MADE BY ROMANIA[J]. Thermal power generation, 2006, (8): 33-35. DOI: 10.19666/j.rlfd.2006.08.011.

  •  
  •  

0

Views

33

下载量

3

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

INFLUENCE OF TWO DIFFERENT PROCESSES FOR SHUTTING DOWN STEAM TURBINE UPON ITS OPERATION AND ROTOR-LIFE EXPENDITURE
ANALYSIS ABOUT ECONOMIC EFFICIENCY OF ONE 330 MW UNIT AFTER INCREASING CAPACITY THROUGH THROTTLING EXTRACTED STEAM FROM HIGH-PRESSURE HEATERS
CAUSE ANALYSIS OF INNER-WALL CRACKING ON HIGH-PRESSURE MAIN STEAM VALVE'S SHELL
SAFETY AND ECONOMIC ANALYSIS OF UNITS USED FOR DEEP PEAK-REGULATING OPERATION IN HEZE POWER PLANT AND RETROFIT MEASURES THEREOF
MEASURES FOR ENHANCING VACUUM IN OPERATION OF CONDENSER

Related Author

REN Hao-ren(Zhejiang Univesity
LI Wei
CHEN Jian-hong
SHENG De-ren
CHEN Feng
MA Wang-peng Huadian Zhenxun Power Generation Co Ltd
CHEN Jue-weiHuaxia International Power Generation Co Ltd
LIU Qi-liang2 1.Department of Power Engineering

Related Institution

Zhejiang University
Huadian Zhenxiong Power Generation Co., Ltd
Huaxia International Power Development Co., Ltd
Guodian Heze Power Plant
Department of Power Engineering, Hebei University of Engineering
0