The resin transfering experience for high speed mixed bed with outside regeneration in condensate polishing treatment system has been presented. The flow behavior of resin
water outlet structure at bottom of the mixed bed
water inlet position of hydraulic transportation
water intake ratio
and pneumatic transportation etc. have been analysed
giving out optimal selection of them combined with reality in the field.