ANALYSIS OF FAULTS COMMONLY OCCURRED IN ELECTRIC CONTROL PART OF THE STATIC PRECIPITATOR IN SONGYU POWER PLANT AND DISPOSAL THEREOF
摘要
Abstract
Directing against problems existing in static precipitator of Songyu Power Plant
such as degradation of equipment
unreasonable design
comparatively higher failure rate
the rate of putting electric field into service can't reach 100%