STATUS INSPECTION AND SERVICE LIFE ASSESSMENT OF WELDED JOINTS BETWEED TP304H / SA213T22 STEELS OF DIFFERENT SORT[J]. Thermal power generation, 2005, (10).
DOI:
STATUS INSPECTION AND SERVICE LIFE ASSESSMENT OF WELDED JOINTS BETWEED TP304H / SA213T22 STEELS OF DIFFERENT SORT[J]. Thermal power generation, 2005, (10). DOI: 10.19666/j.rlfd.2005.10.021.
STATUS INSPECTION AND SERVICE LIFE ASSESSMENT OF WELDED JOINTS BETWEED TP304H / SA213T22 STEELS OF DIFFERENT SORT
Status inspection and service life assessment of welded joints between TP304H / SA213 T22 steels of different sort had been carried out by comprehensively using various testing methods.It had been believed that the welded joint between different steel sorts on sampled tube already reached the end of its service life.Based on this result
the welded joints between different steel sorts on high temperature superheater had been completely retrofitted in a planned major repair in April
2004.The welded joints have been allocated in the space of lower temperature at top of the furnace
a voiding tube replacement in large area after occurrence of leakage.
Thermal fatigue failure analysis for drainage-tank in hot section of reheat pipeline in an ultra supercritical 1 000 MW unit
应用老化因子方法评估高温部件的状态和寿命
A TENTATIVE IDEA FOR ENHANCING THE HIGI-PRESSURE HEATER'S RELIABILITY OF LARGE-SCALE UNITS
APPLICATION OF THICKNESS-DETECTING TECHNOLOGY FOR OXIDE-SCALE ON INNER SIDE OF TUBES TO PREVENT HIGH-TEMPERATURE SUPERHEATER IN A BOILER FROM TUBE-BURSTING
STUDY ON FAILURE MODE OF WELDED JOINTS FOR AUSTENITE STEEL WITH DISSIMILAR METALS ON HIGH-TEMPERATURE BOILER TUBES IN POWER PLANTS
Related Author
LOU Yumin
PENG Yichao
TU Rongfeng
XU Haohao
WANG Xianming
李耀君
任爱
周兰欣
Related Institution
Zhejiang Zhoushan Coal-based Power Co., Ltd.
Zhejiang Energy R&D Co., Ltd.
陕西西安710032
State Power Corporation Thermal Research Institute
Thermal Power Research Institute of State Power Corporation