DAI Haobo, XU Chengliang. STUDY ON AFFECTING FACTORS OF AIRFLOATATION WATERTREATMENT TECHNOLOGY[J]. Thermal power generation, 2005, (8): 56-57.
DOI:
DAI Haobo, XU Chengliang. STUDY ON AFFECTING FACTORS OF AIRFLOATATION WATERTREATMENT TECHNOLOGY[J]. Thermal power generation, 2005, (8): 56-57. DOI: 10.19666/j.rlfd.2005.08.019.
STUDY ON AFFECTING FACTORS OF AIRFLOATATION WATERTREATMENT TECHNOLOGY
摘要
结合溶气气浮工艺的原理
根据有关试验的结果
对影响气浮工艺的主要因素进行分析。认为完全彻底的混凝反应
足够的溶气水与进水的接触时间(不小于40 s)
以及适当的分离区水深
是保证气浮工艺出水水质的关键。
Abstract
Combined with principle of airresolving airfloatation technology
and based on results of related tests
the main factors affecting airfloatation technology have been analysed. It is believed that the key points for ensuring outlet water quality are as follows: completely thorough coagulating reaction; enough contacting time of airresolving water with inlect water (not less than 40s); and keep suitable water depth in separating zone.
INFLUENCE OF PHOSPHEROUS ANTISCALANT USED IN RECYCLING UTILIZATION SYSTEM OF BLOW-DOWN WATER FROM CIRCULATING WATER UPON THE COAGULATION EFFECT
DEVELOPMENT AND APPLICATION OF REMOTE MONITORING SYSTEM FOR CHEMICALS DOSING IN WATER TREATMENT OF POWER PLANTS
EVALUATION METHOD FOR SCALING-RETARDATION BEHAVIOR OF WATER-QUALITY STABILIZING AGENT USED IN CIRCULATING WATER TREATMENT AT THERMAL POWER PLANT
CHEMICAL CLEANING OF THE ULTRAFILTERS
STUDY ON PRESENT SITUATION AND IMPROVEMENT OF CIRCULATORY COOLING WATER TREATMENT IN SOME POWER PLANTS SUBOROINATED TO GUOHUA ELECTRIC POWER CORPORATION
Related Author
WU Jing-ran11.College of Environment Science and Engineering
SUN Xin-li2
CHEN Ying-min1
YANG Wansheng
XU Ting
XU Jianxue
YAN Kun
JIANG Qi
Related Institution
Hebei Electric Power Research Institute
College of Environmental Science and Engineering, North China Electric Power University