LI Lin, WANG Jiu-zhen. CAUSE ANALYSIS AND PROTECTIVE MEASURES FOR CORROSIVE PERFORATION OF CONDENSER’S COPPER TUBES IN YUNFU POWER PLANT[J]. Thermal power generation, 2005, (7): 47-49.
DOI:
LI Lin, WANG Jiu-zhen. CAUSE ANALYSIS AND PROTECTIVE MEASURES FOR CORROSIVE PERFORATION OF CONDENSER’S COPPER TUBES IN YUNFU POWER PLANT[J]. Thermal power generation, 2005, (7): 47-49. DOI: 10.19666/j.rlfd.2005.07.015.
CAUSE ANALYSIS AND PROTECTIVE MEASURES FOR CORROSIVE PERFORATION OF CONDENSER’S COPPER TUBES IN YUNFU POWER PLANT
The causes leading to corrosive perforation of condenser’s copper tubes for units no.3 and no.4 in Yunfu Power Plant have been carried out. Based on analysis results of copper tubes’ composition
corrosion formation
corrosive products
and quality of the circulating water
it is determined that the corrosion type to be pitting attack
and the causes to be residual carbon film existing on inner surface of the copper tubes
as well as the chemical oxygen dissipation (COD) and sulphide content in the water to be over standard. After adopting ferrous sulphate for single filming
and adding suitable amount of antiscalant into the circulating water