WANG xiao-hua, LIAO xiao-chun, TANG Yu-jun. ANALYSIS OF SERIOUSLY FLATTENED OUTER ARC FOR ELBOW BEND PIPES IN DESUPPERHEATERS AND SAFETY EVALUATION THEREOF[J]. Thermal power generation, 2005, (6): 48-49.
DOI:
WANG xiao-hua, LIAO xiao-chun, TANG Yu-jun. ANALYSIS OF SERIOUSLY FLATTENED OUTER ARC FOR ELBOW BEND PIPES IN DESUPPERHEATERS AND SAFETY EVALUATION THEREOF[J]. Thermal power generation, 2005, (6): 48-49. DOI: 10.19666/j.rlfd.2005.06.017.
ANALYSIS OF SERIOUSLY FLATTENED OUTER ARC FOR ELBOW BEND PIPES IN DESUPPERHEATERS AND SAFETY EVALUATION THEREOF
The outer arc of eight elbow bent pipes in a two-stage desuperheater of the superheater for boiler no.4 in Yunfu Power Plant had been seriously flattened
after circularity measurement
thickness measurement
and non-destrutive inspection of said elbow bent pipes
on the basis of GB 9222-88 《Strength calculation of pressurized parts for water tube boilers》
and DL / T 5054-1996 《Technical specifications for designing steam-water pipelines in thermal power plants》
the thickness of the said elbow bend pipes has been calculated for verification respectively
as well as structural stress and film stress of them being computed by using finite element method. Based on synthesizing various results of measurement
inspection
and calculation
it is believed that the said eight elbow bend pipes can still be safe and reliable in operation at present.