您当前的位置:
首页 >
文章列表页 >
ANALYSIS AND TREATMENT OF ABNORMAL VARIATION FOR FIFTH STAGE EXTRACTION STEAM TEMPERATURE CONCERNING 200 MW STEAM TURBINE UNIT
更新时间:2025-09-28
    • ANALYSIS AND TREATMENT OF ABNORMAL VARIATION FOR FIFTH STAGE EXTRACTION STEAM TEMPERATURE CONCERNING 200 MW STEAM TURBINE UNIT

    • Thermal Power Generation   Issue 6, Pages: 40-41(2005)
    • DOI:10.19666/j.rlfd.2005.06.014    

      CLC: TK267
    • Published:2005

    移动端阅览

  • AN Jian-li, DING Yu-jie, DING Liang. ANALYSIS AND TREATMENT OF ABNORMAL VARIATION FOR FIFTH STAGE EXTRACTION STEAM TEMPERATURE CONCERNING 200 MW STEAM TURBINE UNIT[J]. Thermal power generation, 2005, (6): 40-41. DOI: 10.19666/j.rlfd.2005.06.014.

  •  
  •  

0

Views

81

下载量

2

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

Convective heat transfer characteristics of boiler high temperature superheater under pressurized oxygen enrichment condition
Retrofitting of reheaters in 300 MW and 600 MW unit pulverized coal boilers
CAUSE ANALYSIS AND REMEDICAL MEASURES OF LARGER DIFFERENTIAL EXPANSION FOR UNIT NO.4 IN HUANGTAI POWER PLANT
CAUSE ANALYSIS OF SHAFT-PACKING LEAKAGE AND UNSMOOTHLY CLOGGING OF ROTARY DIAPHRAGM FOR C12-35/10 TYPE STEAM TURBINE, AS WELL AS RETROFITTING THEREOF
APPLICATION OF GOVERNOR SYSTEM WITHOUT CONTROLLED WORKING MEDIUM ON 200MW STEAM TURBINE UNIT

Related Author

WANG Lijun
LI Xiaomin
FAN Baoguo
QIAO Xiaolei
LIN Shubiao
CAI Xinchun
XIAO Faqi
JIA Li

Related Institution

School of Architecture and Surveying Engineering, Shanxi Datong University
Guodian Power Datong Power Generation Co., Ltd.
Huangtai Power Plant
Aluminum Corporation of China Shanxi Branch
Aluminum Corporation of China Shanxi Branch Shanxi Hejin
0