PROTECTIVE EFFECT EVALUATION OF FILMING AMINE DURING SHUTPOWN PERIOD OF THERMAL POWER EQUIPMENT[J]. Thermal power generation, 2005, (2): 50-51.
DOI:
PROTECTIVE EFFECT EVALUATION OF FILMING AMINE DURING SHUTPOWN PERIOD OF THERMAL POWER EQUIPMENT[J]. Thermal power generation, 2005, (2): 50-51. DOI: 10.19666/j.rlfd.2005.02.016.
PROTECTIVE EFFECT EVALUATION OF FILMING AMINE DURING SHUTPOWN PERIOD OF THERMAL POWER EQUIPMENT
摘要
讨论了目前常用的成膜胺停运保护效果检测技术
结合现场实际条件
提出一种切实可行的保护效果评价方法
即起动水质对比检验法。通过在首阳山等电厂的应用
证明该方法可以对成膜胺保护效果进行直观明确的评价。
Abstract
Several common used protection techniques during shutdown period by using filming amine have been discussed. Combined with the actual conditions in the field
a practical and feasible protective effect evaluation method
i.e. comparative checking method of water quality at the time of startingup has been put forward. Through application of the said method in Shouyangshan Power Plant and others