TEST AND STUDY ON COOLING TUBE VIBRATION IN CONDENSER OF STEAMTUBINE NO.6 AT HUANENG DEZHOU POWER PLANT[J]. Thermal power generation, 2005, (2): 43-45.
DOI:
TEST AND STUDY ON COOLING TUBE VIBRATION IN CONDENSER OF STEAMTUBINE NO.6 AT HUANENG DEZHOU POWER PLANT[J]. Thermal power generation, 2005, (2): 43-45. DOI: 10.19666/j.rlfd.2005.02.013.
TEST AND STUDY ON COOLING TUBE VIBRATION IN CONDENSER OF STEAMTUBINE NO.6 AT HUANENG DEZHOU POWER PLANT
摘要
对华能德州电厂6号机组凝汽器冷却管的振动和应变测试分析表明
冷却管振动主要是由于凝汽器管束存在一个50 Hz左右的固有振动频率
机组运行中来自转子的激振力使凝汽器管束产生结构共振所致。
Abstract
Test and analysis of cooling tube vibration and strain in condenser of steamturbine No.6 at Huaneng Dezhou Power Plant show that the cooling tube’s vibration is mainly due to an inherint vibration frequency about 50 Hz existing on the tubebunde in said condenser
and the vibration exciting force coming from the rotor in operation of said unit makes the tubebundle to produce structure resonance.