OPTIMIZED RETROFIT OF DUAL CHANNEL BURNERS FOR BOILER NO.1 IN SHIMEN POWER PLANT AND EFFECTNESS THEREOF
The situation of implementing optimized retrofit for self-stabilized dual-channel burners and combustion system of boiler No.1 in Shimen Power Plant has been presented. Through optimized adjustment of the ignition belt and adjustment of inclination angle for the burners
the combustion stability in the entire burners' zone has been enhanced
the temperature of exhaust flue gas being lowered
combustion efficiency being improved by 0.7%
ecomomic effectiveness being obvious
providing refenenced and experience for further resolving the existing problems of comparatively bad counter-interference capability of combustion in boiler No.2 of the above-mentioned power plant. as well as similar problems in other power plants over all the country.