PERFECTION MEASURES FOR COAL FEED SYSTEM OF 100MW CFB BOILER IN FENGYI POWER PLANT[J]. Thermal power generation, 2004, (11): 78-77.
DOI:
PERFECTION MEASURES FOR COAL FEED SYSTEM OF 100MW CFB BOILER IN FENGYI POWER PLANT[J]. Thermal power generation, 2004, (11): 78-77. DOI: 10.19666/j.rlfd.2004.11.028.
PERFECTION MEASURES FOR COAL FEED SYSTEM OF 100MW CFB BOILER IN FENGYI POWER PLANT
摘要
介绍了分宜发电公司 1 0 0MW循环流化床 (CFB)锅炉给煤系统在运行初期出现的问题及其原因
并有针对性地进行了改造。改造后的运行实践表明
给煤系统能够比较平稳地供煤
负荷曲线可控制在± 2 %的通道范围内
保证了锅炉的安全运行
Abstract
Causes leading to and resolving measures of problems occurred in initial period of operation concerning coal feed system of a 100MW circulating fluidized bed (CFB) boiler in Fengyi Power Plant have been presented. Operation practice after retrofitting shows that the coal feed system can more steadily to feed coal
the load curve can be controlled within ±2% range of the path way