GAO Zhiyong, ZHANG Genzhu. CAUSE ANALYSIS AND TREATMENT OF ABNORMAL VIBRATION FOR CENTRIFUGAL FANS[J]. Thermal power generation, 2004, (10): 91-92.
DOI:
GAO Zhiyong, ZHANG Genzhu. CAUSE ANALYSIS AND TREATMENT OF ABNORMAL VIBRATION FOR CENTRIFUGAL FANS[J]. Thermal power generation, 2004, (10): 91-92. DOI: 10.19666/j.rlfd.2004.10.030.
CAUSE ANALYSIS AND TREATMENT OF ABNORMAL VIBRATION FOR CENTRIFUGAL FANS
摘要
对鄂州电厂一次风机异常振动的原因进行了分析
认为该风机轴承、轴承座、风机中心等均存在较大问题
其根本原因是风机存在动不平衡现象。调整后
风机振动值达到了要求
Abstract
The causes leading to abnormal vibration of the primary air fan in Ezhou Power Plant
Hubei Province
have been analysed. It is considered that the comparatively large problems are existing in bearings
bearing pedestals
and fan centre etc.
but the basic reason is dynamic unbalancing phenomenon existing in the fan. After adjustment
the vibration value of the said fan has already reached requirement.