HYBRID COAGULATION AND CLARIFICATION TREATMENT FOR USING SECONDARY URBAN SEWAGE AS MAKEUP WATER OF CIRCULATING COOLING WATER IN THERMAL POWER PLANT[J]. Thermal power generation, 2004, (10): 80-83.
DOI:
HYBRID COAGULATION AND CLARIFICATION TREATMENT FOR USING SECONDARY URBAN SEWAGE AS MAKEUP WATER OF CIRCULATING COOLING WATER IN THERMAL POWER PLANT[J]. Thermal power generation, 2004, (10): 80-83. DOI: 10.19666/j.rlfd.2004.10.025.
HYBRID COAGULATION AND CLARIFICATION TREATMENT FOR USING SECONDARY URBAN SEWAGE AS MAKEUP WATER OF CIRCULATING COOLING WATER IN THERMAL POWER PLANT
After hybrid coagulation and clarification treatment
the secondary urban sewage has satisfied the requirements of specified makeup water quality of the circulating cooling water in a thermal power plant. The practice of Huaneng Beijing Thermal Power Plant shows that the harmfulness of ammonianitrogen
as well as organic substances in the secondary urban sewage after deep treatment can be eliminated by adopting effective scaleinhibiting
corrosionpreventing and sterilizing treatments
as well as scientific technical management after feedingin circulating cooling water system
making the corrosion rate of copper tubing in the condenser to satisfy the requirements of standard.