您当前的位置:
首页 >
文章列表页 >
CALCULATION OF WALL-TEMPERATURE FOR SUPERHEATER AND REHEATER OF HG670/13.7-YM13 TYPE BOILER
更新时间:2025-09-28
    • CALCULATION OF WALL-TEMPERATURE FOR SUPERHEATER AND REHEATER OF HG670/13.7-YM13 TYPE BOILER

    • Thermal Power Generation   Issue 10, Pages: 50-51(2004)
    • DOI:10.19666/j.rlfd.2004.10.015    

      CLC: TK223.3
    • Published:2004

    移动端阅览

  • LIU Tong, XU Gang. CALCULATION OF WALL-TEMPERATURE FOR SUPERHEATER AND REHEATER OF HG670/13.7-YM13 TYPE BOILER[J]. Thermal power generation, 2004, (10): 50-51. DOI: 10.19666/j.rlfd.2004.10.015.

  •  
  •  

0

Views

159

下载量

1

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

ESTABLISHMENT OF SERVICE LIFE MANAGEMENT SYSTEM FOR HIGH-TEMPERATURE BOILER TUBES IN THERMAL POWER PLANT BASED ON B/S STRUCTURE
ON-LINE MONITORING OF TUBE-WALL TEMPERATURE FOR SUPERHEATER AND REHEATER IN FURNACE OF SUPER CRITICAL BOILERS
TEST STUDY ON CONTROLLING HEAT DEVIATION IN UTILITY BOILERS BY USING JET-FLOW READJUSTING METHOD
SEVERAL PROBLEMS EXISTING IN OPERATION OF SUPERCRITICAL AND ULTRA-SUPERCRITICAL BOILERS
INFLUENCE OF OXYGEN TREATMENT FOR SUPERCRITICAL UNITS UPON FORMATION AND PEEL-OFF OF OXIDE SKIN

Related Author

DU Bao-hua
LI Yao-jun
LIU Zhen-yu
LI Chung-min
WANG Zhong-jie
SUN Xi(Xi'an Thermal Power Reseach Institute Co.Ltd
GU ShanGuodian Changzhou Power Plant
LIU Xin-zhi1

Related Institution

Xi'an Thermal Power Research Institute Co., Ltd
Guodian Changzhou Power Plant
School of Power Engineering, Nanjing University of Science and Technology
Shanghai Wangte Energy Technology Co., Ltd
Guodian Jianbi Power Plant
0