ZHAI Pei qiang. AN APPROACH TO OPERATING MODE OF CIRCULATING WATER PUMP FOR 300MW UNIT[J]. Thermal power generation, 2004, (7): 52-54.
DOI:
ZHAI Pei qiang. AN APPROACH TO OPERATING MODE OF CIRCULATING WATER PUMP FOR 300MW UNIT[J]. Thermal power generation, 2004, (7): 52-54. DOI: 10.19666/j.rlfd.2004.07.015.
AN APPROACH TO OPERATING MODE OF CIRCULATING WATER PUMP FOR 300MW UNIT
摘要
通过对 1台 30 0MW机组循环水泵运行方式与机组经济性关系的定量分析
提供了一种以循环水进水温度来确定循环水泵经济调度的方法
并给出了详细的计算过程
Abstract
Through quantitative analysis of relationship between the operating mode of circulating water pump and the economic behavior of a 300MW unit
a method of economic dispatch for circulating water pump determined by inlet water temperature of circulating water has been provided