DESIGN FOR RETROFITTING ECONOMIZER OF A 670t/h PULVERIZED COAL BOILER[J]. Thermal power generation, 2004, (4): 40-44.
DOI:
DESIGN FOR RETROFITTING ECONOMIZER OF A 670t/h PULVERIZED COAL BOILER[J]. Thermal power generation, 2004, (4): 40-44. DOI: 10.19666/j.rlfd.2004.04.012.
DESIGN FOR RETROFITTING ECONOMIZER OF A 670t/h PULVERIZED COAL BOILER
摘要
为了解决耒阳电厂 6 70t/h煤粉锅炉排烟温度过高的问题
经试验分析
提出了省煤器改造的 4种方案
并详细比较分析了各种方案的优缺点
最终确定在现有光管省煤器之上加一部分螺旋肋片管的改造方案。方案实施后
排烟温度降低约 2 2℃
且改造工作量小、投资少
具有很好的经济性和推广价值。
Abstract
In order to solve the problem of undue high exhaust gas temperature of a 670t/h pulverized coal boiler
four schemes of retrofitting the economiser have been put forward on the basis of measurement
test
and theoritical analysis
strong and weak points of each scheme being carefully compared and analysed. Finally
it is determined to use a scheme of adding partial spiral ribbed tubes to the existing economizer of smooth tubes. After implementation of the said scheme