ANALYSIS OF LARGE TEMPERATURE DIFFERENCE OCCURRED ON BEARING SHOE NO.5 AND NO.6 OF LOWPRESSURE CYLINDER IN STEAM TURBINE NO.1 AT GUOHUA ZHUNGEER POWER PLANT
|更新时间:2025-09-28
|
ANALYSIS OF LARGE TEMPERATURE DIFFERENCE OCCURRED ON BEARING SHOE NO.5 AND NO.6 OF LOWPRESSURE CYLINDER IN STEAM TURBINE NO.1 AT GUOHUA ZHUNGEER POWER PLANT
Thermal Power GenerationIssue 11, Pages: 72-73(2003)
ANALYSIS OF LARGE TEMPERATURE DIFFERENCE OCCURRED ON BEARING SHOE NO.5 AND NO.6 OF LOWPRESSURE CYLINDER IN STEAM TURBINE NO.1 AT GUOHUA ZHUNGEER POWER PLANT[J]. Thermal power generation, 2003, (11): 72-73.
DOI:
ANALYSIS OF LARGE TEMPERATURE DIFFERENCE OCCURRED ON BEARING SHOE NO.5 AND NO.6 OF LOWPRESSURE CYLINDER IN STEAM TURBINE NO.1 AT GUOHUA ZHUNGEER POWER PLANT[J]. Thermal power generation, 2003, (11): 72-73. DOI: 10.19666/j.rlfd.2003.11.023.
ANALYSIS OF LARGE TEMPERATURE DIFFERENCE OCCURRED ON BEARING SHOE NO.5 AND NO.6 OF LOWPRESSURE CYLINDER IN STEAM TURBINE NO.1 AT GUOHUA ZHUNGEER POWER PLANT
摘要
针对国华准格尔电厂ALSTOM公司 330MW机组在调试期间出现的低压缸 5号、6号温差大的问题
综合国内同型机组 3种处理方案进行分析、比较
提出采用调整轴瓦底部垫铁间隙及轴承结合面螺栓紧力的处理方案
实施后取得良好效果
Abstract
Directing against the problem of large temperature difference occurred on bearing shoe No.5 and No.6 of lowpressure cylinder in a 330MW steam turbine made by ALSTOM CO. at the title power plant
three remedial schemes used on domestic units of the same type have been analysed. Finally
a scheme of adjusting spacer block clearance under the bottom of bearing shoe
as well as fastening force of bolts on the joint surface of said bearing
has been put forward. After implementation of the said scheme