您当前的位置:
首页 >
文章列表页 >
CAUSE ANALYSIS AND REMEDICAL MEASURES FOR BURN-OUT FAILURE OF FAN'S DUALSUPPORT BEARING DUE TO HEATING IN YUNFU POWER PLANT
更新时间:2025-09-28
    • CAUSE ANALYSIS AND REMEDICAL MEASURES FOR BURN-OUT FAILURE OF FAN'S DUALSUPPORT BEARING DUE TO HEATING IN YUNFU POWER PLANT

    • Thermal Power Generation   Issue 9, Pages: 40-41(2003)
    • DOI:10.19666/j.rlfd.2003.09.013    

      CLC: TM621.3
    • Published:2003

    移动端阅览

  • ZENG De-qi. CAUSE ANALYSIS AND REMEDICAL MEASURES FOR BURN-OUT FAILURE OF FAN'S DUALSUPPORT BEARING DUE TO HEATING IN YUNFU POWER PLANT[J]. Thermal power generation, 2003, (9): 40-41. DOI: 10.19666/j.rlfd.2003.09.013.

  •  
  •  

0

Views

30

下载量

2

CSCD

Alert me when the article has been cited
提交
Tools
Download
Export Citation
Share
Add to favorites
Add to my album

Related Articles

DISCUSSION ON HIGH AXIAL VIBRATION OF INDUCED DRAFT FAN
Reason analysis for fracture occurred in axial induced draft fan blade of a 600 MW unit
Analysis of sulfates deposition on induced draft fan blade in a coal-fired power plant with ultra-low emission
Flue gas recirculation scheme for double-reheat boilers
Operating state and fatigue life evaluation of boiler steam drum for domestic first set of 9F gas turbine units

Related Author

谢澄
GU Weiwei
ZHANG Yonghai
LI Yuan
YU Xiaobing
SHI Zhigang
WANG Yibin
TAN Houzhang

Related Institution

Beilun Power Plant
Xi’an Thermal Power Research Institute Co., Ltd.
Xi’an TPRI Energy Conservation Technology Co., Ltd.
Shenhua Guohua (Beijing) Electric Power Research Institute Co.Ltd
0