TEMPERATURE FIELD AND THERMAL STRESS FINITE ELEMENT ANALYSIS OF A 50MW STEAM TURBINE'S CYLINDER IN A POWER PLANT[J]. Thermal power generation, 2003, (9): 21-24.
DOI:
TEMPERATURE FIELD AND THERMAL STRESS FINITE ELEMENT ANALYSIS OF A 50MW STEAM TURBINE'S CYLINDER IN A POWER PLANT[J]. Thermal power generation, 2003, (9): 21-24. DOI: 10.19666/j.rlfd.2003.09.006.
TEMPERATURE FIELD AND THERMAL STRESS FINITE ELEMENT ANALYSIS OF A 50MW STEAM TURBINE'S CYLINDER IN A POWER PLANT
A three dimentional finite element analysis of the temperature field and the thermal stress field regarding a 50MW steam turbine’s high pressure cylinder in a powr plant under different operation conditions has been carried out. The results show
the position of calculated max. stress tallies completely with that of the cracked cylinder
providing important technical basis for evaluating the steam cylinder’s safety and calculating the said cylinder’s residual service-life.