1. 河南电力试验研究所
2. 河南电力试验研究所,河南,郑州,450052
3. ,河南,郑州,450052
Published:2003
移动端阅览
BENDING ROTOR'S VIBRATION CONTROL OF STEAM TURBINE FOR A 300MW UNIT[J]. Thermal power generation, 2003, (3): 64-65.
DOI:
BENDING ROTOR'S VIBRATION CONTROL OF STEAM TURBINE FOR A 300MW UNIT[J]. Thermal power generation, 2003, (3): 64-65. DOI: 10.19666/j.rlfd.2003.03.021.
针对某国产 30 0MW机组汽轮机高压转子弯曲故障
进行了转子振动响应和不平衡量计算分析。采用单转子高速动平衡校正与更换可倾瓦轴承等措施
使轴振动幅值降低至合格范围。
In view of the high-pressure rotor’s bending fault occurred on steam turbine of a home-made 300MW unit
the rotor’s vibration response and the unbalanced component have been calculated and analyzed. Some measures
such as single rotor high-speed dynamic equilibrum
correction and inclinable bearing shoe’s application
have been taken
enabling the vibration amplitude to reduce to a region up to standard.
0
Views
166
下载量
1
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution