PANG Hua-hao. ANALYSIS OF EXISTING TROUBLESOME PROBLEMS ON CONDENSATE PUMPS AT ZHANJIANG POWER PLANT AND TREATMENT THEREOF[J]. Thermal power generation, 2003, (1): 74-75.
DOI:
PANG Hua-hao. ANALYSIS OF EXISTING TROUBLESOME PROBLEMS ON CONDENSATE PUMPS AT ZHANJIANG POWER PLANT AND TREATMENT THEREOF[J]. Thermal power generation, 2003, (1): 74-75. DOI: 10.19666/j.rlfd.2003.01.023.
ANALYSIS OF EXISTING TROUBLESOME PROBLEMS ON CONDENSATE PUMPS AT ZHANJIANG POWER PLANT AND TREATMENT THEREOF
The existing troublesome problems on title conden sate pumps are as follows: (1) the fastening bolts at movable flange joint of connecting pipe are easy to be brocken; (2) the packing shaft sleeves are easy to be worn-out; (3) large amount of water-leakage from gland packing
etc.. For these problems
retrofit of related parts has been carried out: (1) the movable connecting pipe has been changed into a fixed one; (2) single end-face container type mechanical seal manufactured from UK has been installed. After retrofitting