STUDY ON THE INFLUENCE OF RESIDUAL CARBON FILM UPON EARLY PERFORATED CORROSION ON BRASS TUBES OF THE CONDENSOR[J]. Thermal power generation, 2002, (6): 64-67.
DOI:
STUDY ON THE INFLUENCE OF RESIDUAL CARBON FILM UPON EARLY PERFORATED CORROSION ON BRASS TUBES OF THE CONDENSOR[J]. Thermal power generation, 2002, (6): 64-67. DOI: 10.19666/j.rlfd.2002.06.020.
STUDY ON THE INFLUENCE OF RESIDUAL CARBON FILM UPON EARLY PERFORATED CORROSION ON BRASS TUBES OF THE CONDENSOR
摘要
通过对几个电厂凝汽器新铜管短期发生腐蚀穿孔事例的研究和分析
确定其是由管内表面存在残碳膜而引起。探讨了有关机理
并提出了消除和避免管内表面存在残碳膜的措施
Abstract
Through study and analysis of perforated corrosion events occurred on new brass tubes of condensors in several power plants
it is confirmed that the said events were caused by residual carbon films on inner surface of the tubes. Hence
related mechanisms have been discussed
and measures to eliminate and avoid occurrence of residual carbon film on the inner surface of brass tubes being put forward.