REVERSE TANGENTIAL RETROFITTING OF BURNERS USED FOR CORNER TANGENTIAL FIRING IN ZHUJIANG POWER PLANT[J]. Thermal power generation, 2002, (6): 33-36.
DOI:
REVERSE TANGENTIAL RETROFITTING OF BURNERS USED FOR CORNER TANGENTIAL FIRING IN ZHUJIANG POWER PLANT[J]. Thermal power generation, 2002, (6): 33-36. DOI: 10.19666/j.rlfd.2002.06.011.
REVERSE TANGENTIAL RETROFITTING OF BURNERS USED FOR CORNER TANGENTIAL FIRING IN ZHUJIANG POWER PLANT
摘要
针对珠江电厂 2号炉末级再热器AB侧烟温偏差较大
末级再热器后局部烟温比设计烟温高的问题
使用CFXTASCFLOW三维流动燃烧传热计算软件对炉内燃烧工况进行模拟计算
最终确定了燃烧器反切改造方案
并在改造方案实施后对锅炉燃烧进行了优化调整。测试结果表明
燃烧器改造后末级再热器AB侧烟温偏差下降了 36℃
断面最高烟温平均下降了 30℃
末级再热器管壁最高温度下降了 4℃~ 10℃
减少了锅炉超温爆管的危险
有效保证了锅炉安全经济运行
Abstract
In the light of troublesome problems occurred on boiler No.2 in Zhujiang Power Plant
such as larger deviation of flue gas temperature at A
B side after final stage reheater
and temperature of partial flue gas being higher than the designed value
analog computation of combustion performance in the furnace has been carried out by using the CFX-TASCFLOW heat transfer calculating software for three dimensional flowing combustion
and finally a scheme of reverse tangential retrofitting of the burners is determined
and optimizing adjustment of combustion in the boiler is performed after implementation of the retrofitting scheme. The results of test show
after retrofitting the burners
the flue gas temperature deviation at A
B side having been lowered to be 36℃
the max
flue gas temperature evenly lowered to be 30℃
the max
tube wall temperature lowered to be 4~10℃
the risk of boiler tube burst due to over temperature being reduced
effectively ensuring safe and economic operation of the boiler.