摘要
分析了高坝发电厂 4 10t/h循环流化床 (CFB)锅炉的大量运行和试验数据
以及锅炉负荷率、炉膛气速、床压、床温等主要运行参数对炉膛受热面平均传热系数的影响及相互之间的关系
得出了一些比较有规律性的结果。这些结果对于CFB锅炉的设计、研制及运行具有较高的参考价值
Abstract
A vast amount of operational and experimental data for a 410t/h CFB boiler in Gaoba Power Plant
as well as the influence of its main operational parameters
such as boiler load factor
gas velocity in furnace
bed pressure
and bed temperature etc.
upon the average heat transfer coeficient of heating surface in the furnace
and the mutual relationship among the said parameters have been analysed
some results with better regularities are obtained. These results have comparatively high reference value for design