LIANG Qun-hua. RETROFIT AND ANALYSIS OF SERVOMOTOR IN SPEED-GOVERNING SYSTEM OF STEAM TURBINE FOR C50 TYPE UNIT[J]. Thermal power generation, 2002, (2): 47-49.
DOI:
LIANG Qun-hua. RETROFIT AND ANALYSIS OF SERVOMOTOR IN SPEED-GOVERNING SYSTEM OF STEAM TURBINE FOR C50 TYPE UNIT[J]. Thermal power generation, 2002, (2): 47-49. DOI: 10.19666/j.rlfd.2002.02.014.
RETROFIT AND ANALYSIS OF SERVOMOTOR IN SPEED-GOVERNING SYSTEM OF STEAM TURBINE FOR C50 TYPE UNIT
After putting C50 type unit into operation at Guangzhou Power Plant
it was foun d that the dynamic characteristic of its speed-governing system isn′t up to standard via full load rejection experiment. Through retrofitting the servomotor in said governing system
the actuation slowness of the speed governing system has been improved
enhancing the closing velocity of the servomotor
and then the problem regarding the excesive overshoot of the dynamic characteristic for the speed-governing system having been resolved.