LI Xing-long. ANALYSIS ON THERMAL FATIGUE OF WATER WALL TUBES IN BOILER NO1 AT SHIMEN POWER PLANT[J]. Thermal power generation, 2001, (4): 61-63.
DOI:
LI Xing-long. ANALYSIS ON THERMAL FATIGUE OF WATER WALL TUBES IN BOILER NO1 AT SHIMEN POWER PLANT[J]. Thermal power generation, 2001, (4): 61-63. DOI: 10.19666/j.rlfd.2001.04.019.
ANALYSIS ON THERMAL FATIGUE OF WATER WALL TUBES IN BOILER NO1 AT SHIMEN POWER PLANT
摘要
通过对裂纹的宏观、微观分析及内壁结垢的成分分析
认为石门电厂 1号炉水冷壁泄漏主要是由于给水硬度超标后结垢
引起传热恶化
使材料的机械性能下降
以及机组运行及启停过程中产生的交变热应力导致水冷壁热疲劳所致
对此提出了具体的防范措施
Abstract
Macroanalysis
microanalysis for the crack and composition analysis for chemical deposits on inner tubes are conducted. It demonstrates that main reasons of water wall leakage of boiler No.1 at Shimon plant are as follows: the mechanical property of material reduced due to feed water depositing and heat transfer deterioration
the thermal fatigue of water wall because of alternative thermal stress during unit operation
startup and shutdown. As a result
Specific preventative measures of water wall tubes failure are put forward