GUO Qi-xiang. EXPERIMENT STUDY ON HP HEATER FOR TURBINE No.1 IN PINGWE1 POWER PLANT[J]. Thermal power generation, 2001, (2): 40-42.
DOI:
GUO Qi-xiang. EXPERIMENT STUDY ON HP HEATER FOR TURBINE No.1 IN PINGWE1 POWER PLANT[J]. Thermal power generation, 2001, (2): 40-42. DOI: 10.19666/j.rlfd.2001.02.014.
EXPERIMENT STUDY ON HP HEATER FOR TURBINE No.1 IN PINGWE1 POWER PLANT
Through the adjustment testing of condensate level in HP heater made from Fost Wheeler Corporations Technology
test of HP heater during start-up and stop of turbine with sliding steam conditions was made
it has been analyzed how the condensate level and temperature change control influnce on the operation of HP heater.In the aspect of condensate level rising and change of control mode is raised a problem
demanding prompt solution
how to deal with the condensate temperature change rate.