CHARACTERISTICS' ANALYSIS FOR OVER SPEED PROTECTION CONTROLLER OF 700 MW UNIT AT ZHUHAI POWER PLANT
摘要
基于失效分析和可靠性预测
应用系统状态部件对国产大容量机组典型电液并存型调节系统可靠性进行分析
给出了机组处于各种状态概率的计算式 ;用马尔柯夫状态转移法对液压调节系统的常见故障模式进行了讨论
给出了可靠性指标的计算式。
Abstract
Combined with four stage load rejection test completed in Zhuhai power plant on unit No 1 of 2×700 MW units
the designed charaterisitics of over speed controller(OPC) of this unit has been analyzed
discussing the requiments for designing the circuits of over speed protection.The result of load rejection test of this unit shows
despite the designed OPC has a number of electronic circuits
but the compensation for power non-equilibrium has been introduced into the speed-controlling circuit
enabling not only the governor valve has fast-closing function
but also the OPC has good adaptability to load reject cases at different loads.