1. 国家电力公司热工研究院,西安,710032
2. 高井发电厂,北京,100042
Published:2000
移动端阅览
DEMONSTRATION PROJECT OF RETROFITTING LOW NOx BURNERS FOR 100 MW COAL-FIRED UNITS[J]. Thermal power generation, 2000, (6): 4-8.
DOI:
DEMONSTRATION PROJECT OF RETROFITTING LOW NOx BURNERS FOR 100 MW COAL-FIRED UNITS[J]. Thermal power generation, 2000, (6): 4-8. DOI: 10.19666/j.rlfd.2000.06.002.
为降低高井电厂 5号炉的NOx 排放量
用 12只HTNR型燃烧器替换了原来的 12只双蜗壳扰动式燃烧器。改造后锅炉低负荷能力较好
可在 50 %负荷下稳定燃烧。NOx 排放量为 140g/GJ~ 170g/GJ之间
In order to reduce the emission of NO x for boiler No 5 in Gaojing Power Plant
twelve double-volute disturbed-type burners had been replaced by using twelve HINR burners.After retrofit
the performance of this boiler under low load operation was better
the stability of combustion can be maintained at 50% of load.The emission of NO x can be kept between 140-170 g/GJ.