TEST OF ECONOMIC PERFORMANCE OF A UPGRADED 48SH-22 CIRCULATING PUMP[J]. Thermal power generation, 2000, (3): 31-32.
DOI:
TEST OF ECONOMIC PERFORMANCE OF A UPGRADED 48SH-22 CIRCULATING PUMP[J]. Thermal power generation, 2000, (3): 31-32. DOI: 10.19666/j.rlfd.2000.03.010.
TEST OF ECONOMIC PERFORMANCE OF A UPGRADED 48SH-22 CIRCULATING PUMP
摘要
珲春发电厂 48SH - 2 2型循环水泵由于运行工况严重偏离设计工况
存在着运行效率低、电耗高、叶轮汽蚀严重等问题。 1997年采用了高效叶轮对循环水泵进行了节能改造
并对电机进行了双速改造。通过性能试验和经济性分析
改造后高速运行水泵效率为 84.7%
低速运行效率为 86 .8%
每年可节电 2 47.7万kW·h
相当于降低供电煤耗率 1.4787g/ (kW·h)。水泵运行调整灵活
能满足不同季节对循环水量的需求
为同类型循环水泵的改造提供了经验
Abstract
Due to deviation from design conditions
a 48SH-22 circulating pump in Huichun power plant was found with many operation problems.such as low operation efficiency
high power consumption
impeller cavitation
etc.For energy saving purpose
this circulating pump was upgraded in 1997 with a two-speed motor and a high-efficient impeller.The results of performance test and economic analysis show that the circulating pump reached an efficiency of 84.7% with high speed and 86.8% with low speed.An annual electricity saving of 2.477 MW·h and a decrease of coal consumption of 1.4787 g/kWh were then obtained.The operation of this upgraded pump is very flexible.It can meet all the water demands in different seasons.