克拉玛依石油化工厂热电厂DG130 / 3.82 - 4形 1号锅炉改造后投用一个月
渣口 12根水冷壁管发生 13处严重泄漏
梳形板失效
经分析其原因为运行及设计欠佳所致
最后给出了改进措施
Abstract
No.1 boiler(DG130/3.82-4)in the thermal power station of Karamayi Oil Refinery was put into operation after modification.One month later
13 places on twelve water-wall tubes at boiler slag discharge opening were found with severe leakage and the tube spacers were damaged too.Analysis snows that it was caused by the inproper operation and desigh.Some proposals for improvement were put forward.