DEGRADATION ANALYSIS AND ANTI-MEASURES FOR NON-FLAMMABLE OIL USED BY AN
IMPORTED 300MW UNIT[J]. Thermal power generation, 1999, (2).
DOI:
DEGRADATION ANALYSIS AND ANTI-MEASURES FOR NON-FLAMMABLE OIL USED BY AN
IMPORTED 300MW UNIT[J]. Thermal power generation, 1999, (2). DOI: 10.19666/j.rlfd.1999.02.014.
DEGRADATION ANALYSIS AND ANTI-MEASURES FOR NON-FLAMMABLE OIL USED BY AN
IMPORTED 300MW UNIT
摘要
介绍国产引进型300MW机组抗燃油系统及运行情况,分析了抗燃油的劣化原因,提出了防止措施。
Abstract
Abstract This paper describes a non-flammable oil system and its operation of an imported 300MW unit. Causes of oil degradation were analyzed and antimeasures were put forward.