VIBRATION DIAGNOSIS AND TROUBLE-SHOOTIN OF NO.3 UNIT IN JINGYUAN POWER PLANT.[J]. Thermal power generation, 1999, (2).
DOI:
VIBRATION DIAGNOSIS AND TROUBLE-SHOOTIN OF NO.3 UNIT IN JINGYUAN POWER PLANT.[J]. Thermal power generation, 1999, (2). DOI: 10.19666/j.rlfd.1999.02.009.
VIBRATION DIAGNOSIS AND TROUBLE-SHOOTIN OF NO.3 UNIT IN JINGYUAN POWER PLANT.
Abstract Based on the vibration measurements on-site
a detail vibration analysis on 3# bearing of No.3 turbine generator unit of Jingyuan Power Plant is presented.It points out that the vibration was mainly caused by the unbalanced coupling of IP and LP rotors and by IP rotor bending due to the rubbing occurred between the stationary and moving parts.A technical proposal was made to solve the vibration problem and the result was very successful.