针对SG1 0 0 0t/h直流锅炉下辐射区爆管问题
进行了炉内热负荷、下辐射区水动力和壁温传热计算和分析。在现有技术基础上
提出二次上升的改进方案
以提高水动力的稳定性和对运行工况变动的适应性
This paper analyzes and calculates the distribution of the tube flow rate
wall temperature and the thernal load for the low portion of the furnace
To solve the problem with tube bursting in the burning zone of the SG1000t/h noce
t
hrough boiler
a second rising of water wall is suggested
and The hydrodynamic stability
thermostability and the suitability of various operations will be strongly improved.