LOW -RANK COAL BURNER WITH STANILIZATION CHAMBER USED IN GUILIN POWER PLANT[J]. Thermal power generation, 1997, (3): 36-46.
DOI:
LOW -RANK COAL BURNER WITH STANILIZATION CHAMBER USED IN GUILIN POWER PLANT[J]. Thermal power generation, 1997, (3): 36-46. DOI: 10.19666/j.rlfd.1997.03.011.
LOW -RANK COAL BURNER WITH STANILIZATION CHAMBER USED IN GUILIN POWER PLANT
For disproving unstable combustion of low rank coal the bumers of boiler No. I in Guilin power plant were modified with stabilzation zone. The test results show that the combustion can be stabilized under 50% capacity without aid of oil guns and the heat efficiency of boiler was raised by 4%.