A STUDY ON PASSIVATING CONDITION IN BOILER CHEMICAL CLEANING PROCESS BY POTENTIAL SCANING ANODIC POLARIZATION[J]. Thermal power generation, 1996, (6).
DOI:
A STUDY ON PASSIVATING CONDITION IN BOILER CHEMICAL CLEANING PROCESS BY POTENTIAL SCANING ANODIC POLARIZATION[J]. Thermal power generation, 1996, (6). DOI: 10.19666/j.rlfd.1996.06.009.
A STUDY ON PASSIVATING CONDITION IN BOILER CHEMICAL CLEANING PROCESS BY POTENTIAL SCANING ANODIC POLARIZATION
A study on passivating parameter in boilers chemical cleaning process is for the first time in China carried out with potential scanning anodic polarization technique. At first
a suitable scanrate was selected through experiment
then the active-passive transition potential
passive region
passive- transpassivation transition potential and pitting trend of carbonsteels were determined in 0. 3% HL solutions with various PH and CI- concentration. The results show that the main parameters should be controlled as following
pH >9. 0(>9. 5 if presence of Cl-)
[Cl-]<100mg/L
and adequate oxidizerconcentration in order to form tight
adherent and Protective film at the surface of carbon steels during passivating.