CAUSE ANALYSIS OF WATERWALL TUBES BURST IN BOILER NO.1 IN DATONG POWER PLANT No.2[J]. Thermal power generation, 1996, (4).
DOI:
CAUSE ANALYSIS OF WATERWALL TUBES BURST IN BOILER NO.1 IN DATONG POWER PLANT No.2[J]. Thermal power generation, 1996, (4). DOI: 10.19666/j.rlfd.1996.04.005.
CAUSE ANALYSIS OF WATERWALL TUBES BURST IN BOILER NO.1 IN DATONG POWER PLANT No.2
macro-and micro - analysis of the waterwall tube failure in boiler No.1.Datong power plant No.2 shows that the tube burst was caused by the combined action of caustic corrosion and creep.The caustic corrosion was found to ho the main contributor
and the creep-promoter accelarating the final failure of the tubes.Therefore
the final fracture has the from of uniform corrosion pits and local axial cracking.