LIFE ASSESSMENT OF CIRCUMFERENTIAL WELD SEAMS ON A 300 MW BOILER DRUM AWLER WELD REPAIRING[J]. Thermal power generation, 1995, (4).
DOI:
LIFE ASSESSMENT OF CIRCUMFERENTIAL WELD SEAMS ON A 300 MW BOILER DRUM AWLER WELD REPAIRING[J]. Thermal power generation, 1995, (4). DOI: 10.19666/j.rlfd.1995.04.001.
LIFE ASSESSMENT OF CIRCUMFERENTIAL WELD SEAMS ON A 300 MW BOILER DRUM AWLER WELD REPAIRING
This paper describes a study of life assessment of circumferential weld seams on a 300 MW boiler drum. Because of defeats
the weld seams bud to be repaired. After several repairs
the size and shape of the weld seams were quite different from the original design.After necessary inspection to the weld seams and base material