THE TEMPERATURE FIELD IN THE STEAM GENERATOR DRUM WALL FOR CYCLE LOADING UNITS[J]. Thermal power generation, 1993, (3): 3-12.
DOI:
THE TEMPERATURE FIELD IN THE STEAM GENERATOR DRUM WALL FOR CYCLE LOADING UNITS[J]. Thermal power generation, 1993, (3): 3-12. DOI: 10.19666/j.rlfd.1993.03.001.
THE TEMPERATURE FIELD IN THE STEAM GENERATOR DRUM WALL FOR CYCLE LOADING UNITS
摘要
本文根据贝塞尔函数的性质及其多项式表达式
通过理论分析求解
得到汽包锅炉调峰运行时汽包壁温的解析解表达式。用于实际计算表明
该解析解可以很方便地用计算机计算。
Abstract
According to the properties of Bessel function and its polynomial expression
the analysis expression of temperature field in the steam generator drum wall for cycle loading units is obtained in this paper. The practice showes that the analysis expression can be solved by a computer conveniently.