Multi-Phase Stacked Interleaved Buck Converter for Hydrogen-Production Electrolysis with Low-Voltage-Stress Ripple Compensation Circuit
Regular Papers|更新时间:2026-03-25
|
Multi-Phase Stacked Interleaved Buck Converter for Hydrogen-Production Electrolysis with Low-Voltage-Stress Ripple Compensation Circuit
CSEE Journal of Power and Energy SystemsVol. 12, Issue 1, Pages: 401-410(2026)
作者机构:
1. Department of Electrical Engineering, Key Laboratory of Power Electronics for Energy Conservation and Drive Control of Hebei Province, Yanshan University,Qinhuangdao,China
2. Shenke Technology Group Co., Ltd.,Shijiazhuang,China
Le Sun, Zhaoguo Liu, Xiaoqiang Guo, et al. Multi-Phase Stacked Interleaved Buck Converter for Hydrogen-Production Electrolysis with Low-Voltage-Stress Ripple Compensation Circuit[J]. CSEE Journal of Power and Energy Systems, 2026, 12(1): 401-410.
DOI:
Le Sun, Zhaoguo Liu, Xiaoqiang Guo, et al. Multi-Phase Stacked Interleaved Buck Converter for Hydrogen-Production Electrolysis with Low-Voltage-Stress Ripple Compensation Circuit[J]. CSEE Journal of Power and Energy Systems, 2026, 12(1): 401-410. DOI: 10.17775/CSEEJPES.2022.07090.
Multi-Phase Stacked Interleaved Buck Converter for Hydrogen-Production Electrolysis with Low-Voltage-Stress Ripple Compensation Circuit
A multi-phase stacked interleaved buck converter (SIBC) is suitable for large-power water electrolysis applications due to its merits of high current output capability and zero output current ripple. However
the auxiliary converter used to compensate for the current ripple still has to withstand high voltage stress. This paper proposes a new multi-phase SIBC applied in the multicarrier energy system integrating electricity
heat
and hydrogen. A resistor-capacitor voltage divider is used to provide the input voltage of the auxiliary converter and as a heater for the thermal loads. Thus
the voltage stress of the auxiliary converter can be reduced at a low cost
and the size of the filter inductor can be reduced. With accurate voltage and current analysis and appropriate parameter design
the voltage stresses of both the switches and capacitors in the auxiliary converter can be further limited within an expected range. The experimental results verify the correctness of the topology
modulation
analysis
and design methods. A comparison with the conventional method is made in terms of cost
volume
and efficiency to show the advantages of the proposed method.
Renewable generation capacity and reliability assessments for resilient active distribution networks based on time-sequence production simulation
Decentralized Dispatch with Distributionally Robust Joint Chance Constraints for Integrated Electrical and Heating System via Dynamic Boundary Response
Self-Balancing Three-Phase Five-Level Inverter with Reduced DC Bus Voltage
Prescriptive Decision-Making in Nested Bi-Level MO-IGDT Model for Integrating Parking Lots into Local Multi-Carrier Energy System
Hybrid AC/DC Collection and HVDC Transmission Topology for Large-scale Offshore Wind Farms
Related Author
Qianheng Gao
Junpeng Zhu
Yue Yuan
Chang Yang
Zhengshuo Li
Yixun Xue
Wenyuan Zhang
Hongliang Wang
Related Institution
Department of Energy and Electrical Engineering, Hohai University
School of Electrical Engineering, Shandong University
School of Electrical Engineering, Taiyuan University of Technology
College of Electrical and Information Engineering, Hunan University
Electrical Engineering Department, Qatar University