Jianwen Li, Xiaotang Ma, Binyuan Wu, et al. Robust Control Delay Compensation Method for Grid Connected Inverter Based on Improved Newton Interpolation[J]. CSEE Journal of Power and Energy Systems, 2025, 11(2): 783-792.
DOI:
Jianwen Li, Xiaotang Ma, Binyuan Wu, et al. Robust Control Delay Compensation Method for Grid Connected Inverter Based on Improved Newton Interpolation[J]. CSEE Journal of Power and Energy Systems, 2025, 11(2): 783-792.DOI: 10.17775/CSEEJPES.2021.07230.
Robust Control Delay Compensation Method for Grid Connected Inverter Based on Improved Newton Interpolation
摘要
Abstract
The LCL grid-connected inverter makes extensive use of capacitive current feedback active damping because of its good resonance peak suppression performance. However
the existence of control delay under digital control weakens the effect
resulting in possible instability of the system. To enhance the robustness of capacitive current feedback control
a delay compensation strategy for an LCL grid-connected inverter is proposed in this paper. The strategy uses the improved Newton interpolation to predict the actual control signal
which is equivalent to providing the leading phase for the forward channel of grid connected current loop. In such way
it can maintain the effectiveness of inverter active damping and strengthen the stability of the system. Furthermore
compared with the traditional Newton interpolation delay compensation
the proposed strategy integrates the computation delay and pulse width modulation delay
thus expanding the control delay compensation range. The under compensation problem caused by limited compensation ability can be avoided. Finally
simulations and experiments confirm the effectiveness of this proposed control strategy.