Hongyang Zhou, Guoming Ma, Meng Zhang, et al. Insulation Design Rule for a Spacer in SF6/N2-filled DC Gas Insulated Apparatus[J]. CSEE Journal of Power and Energy Systems, 2024, 10(2): 727-735. DOI: 10.17775/CSEEJPES.2020.02100.
DOI:
Hongyang Zhou, Guoming Ma, Meng Zhang, et al. Insulation Design Rule for a Spacer in SF6/N2-filled DC Gas Insulated Apparatus[J]. CSEE Journal of Power and Energy Systems, 2024, 10(2): 727-735. DOI: 10.17775/CSEEJPES.2020.02100.DOI:
Insulation Design Rule for a Spacer in SF6/N2-filled DC Gas Insulated Apparatus
摘要
Abstract
A recurring challenge of a DC SF
6
/N
2
-filled GIS/GIL apparatus is the charge accumulation at DC stress. The conventional design rules and knowledge of AC spacers may not be applicable for this new type of apparatus. A novel design rule is proposed considering the effect of accumulated charge on the threshold of electric field strength being resistant to the superposed voltage. A surface charge accumulation simulation model is introduced
and the key parameters in the simulation model are measured. In addition
an experimental platform for a 100 kV spacer flashover test is established. Spacer flashover tests under superimposed voltage with opposing polarities are carried out
and the withstanding voltage of the spacer is obtained. Finally
based on the proposed model
the threshold of the surface electric field strength (tangential component) on the DC spacer in SF
6
/N
2
mixed gases is discussed. For a reliable insulation design of a DC GIS/GIL apparatus filled with 0.7 MPa SF
6
/N
2
the threshold of surface electric field strength on the DC spacer is 12 kV/mm. The insulation design rule can
be referenced in the design of a high-voltage DC SF