Xianggen Yin, Zhe Zhang, Xuanwei Qi, et al. Modeling and analysis for practical CT based on transient test and parameter identification[J]. CSEE Journal of Power and Energy Systems, 2016, 2(4): 51-57.
DOI:
Xianggen Yin, Zhe Zhang, Xuanwei Qi, et al. Modeling and analysis for practical CT based on transient test and parameter identification[J]. CSEE Journal of Power and Energy Systems, 2016, 2(4): 51-57. DOI: 10.17775/CSEEJPES.2016.00049.
Modeling and analysis for practical CT based on transient test and parameter identification
摘要
Abstract
In the transient process of power grid faults
the transferring distortion of current transformer (CT) can seriously affect relay protection performance. Under these conditions
it is difficult to analyze the ferromagnetic characteristic of the magnetizing branch in the transient equivalent circuit of CT. The Jiles-Atherton hysteresis model (J-A model)
which is widely used in digital simulations
can accurately describe the hysteresis and saturation process of the core characteristics; however
to acquire the parameters of the J-A model of current transformers in practical use is still a challenging problem. In this paper
physical tests based on a practical CT and parameter identification are presented to solve the problem. The basic hysteresis loops of P
PR
and TPY class of practical current transformers are obtained through physical tests. Thus
the J-A model parameters are identified using a hybrid genetic/simulated annealing algorithm
based on which transient simulation models of different class CTs are constructed. The effectiveness of the proposed method is verified via dynamic physical simulation tests. A typical accident is analyzed based on these models.
Influence of Parasitic Parameters on Dynamic Threshold Voltage Hysteresis of Silicon Carbide MOSFETs
Direction Protection Based on Time-domain Travelling Wave for Flexible MTDC Grid
Droop Control Method to Achieve Maximum Power Output of Photovoltaic for Parallel Inverter System
Time-domain finite element method for transient electric field and transient charge density on dielectric interface
Coupling Characteristics of DFIG-based WT Considering Reactive Power Control and Its Impact on Phase/Amplitude Transient Stability in a Rotor Speed Control Timescale
Related Author
Yumeng Cai
Tong Sun
Peng Sun
Zhibin Zhao
Xuebao Li
Hui Wang
Zhong Chen
Boyuan Cao
Related Institution
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University
Department of Electrical Engineering, University of Arkansas
Electric Power Research Institute, State Grid Shanghai Electric Power Company
State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology
Key Laboratory of Smart Grid of Ministry of Education, Tianjin University