WANG Bing, HU Xiao-bo, KONG Nan-nan. Experimental study on vacuum combined with electro-osmosis
for reinforcing ultrafine particle dredged soil[J]. 2025, 46(11): 3523-3533+3636.
DOI:
WANG Bing, HU Xiao-bo, KONG Nan-nan. Experimental study on vacuum combined with electro-osmosis
for reinforcing ultrafine particle dredged soil[J]. 2025, 46(11): 3523-3533+3636.DOI: 10.16285/j.rsm.2025.0089.
Experimental study on vacuum combined with electro-osmosis
for reinforcing ultrafine particle dredged soil
真空预压作为一种常见的处理高含水率饱和软土的地基加固方式,在大面积围海造陆工程中应用广泛。但是在许多真空预压加固饱和软土的工程案例中存在加固后地基承载力偏低,尤其是深层土体强度提高幅度有限的情况。大量研究表明,真空预压的加固效果受限于两个核心因素:真空度随深度的衰减效应以及细颗粒在排水板附近的富集对水流路径的阻塞作用。针对上述问题,依托乐清湾北港区吹填工程,提出在真空预压加固后期,采用电渗联合真空预压(electro-osmosis with vacuum preloading,简称EVP)进行短期加固以研究土体强度增长规律。试验通过采用大尺寸模型试验池的方式,先按正常的真空预压步骤抽气108 d,待沉降曲线稳定后,开启电渗联合真空预压加固。该阶段分为两个小的阶段,第1阶段持续11 d,然后对阴阳极进行互换开启第2阶段电渗联合真空预压试验,第2阶段持续6.5 d,共进行17.5 d电渗联合真空预压加固。经电渗联合真空预压加固后,20、60、100 cm 3个深度的土体含水率分别降低4.2%、4.84%、2.34%,十字板强度分别提高32%、75%、61.1%。试验结果表明:真空预压后期通过叠加电渗法,可在含水率降幅小于5%的情况下,实现十字板强度较大幅度的提升,特别是对于原先强度较低,单纯真空预压法加固困难的深层土体,强度提升了61%~75%,具有较好的加固效果。
Abstract
Vacuum preloading
as a widely adopted ground improvement method for saturated soft soils with high water content
is extensively applied in large-scale coastal reclamation projects. However
post-reinforcement bearing capacity remains insufficient in many engineering cases
particularly with limited strength improvement in deep soil layers. Numerous studies have demonstrated that the consolidation efficiency of vacuum preloading is constrained by two critical factors: depth-dependent attenuation of vacuum pressure and fine particle enrichment-induced clogging of drainage paths near prefabricated vertical drains. To address these challenges
this study integrates electro-osmosis with vacuum preloading (EVP) during the later stage of vacuum preloading in the dredger fill project of Yueqing Bay North Port Area. A large-scale model test pool was employed
where conventional vacuum preloading was conducted for 108 days until settlement stabilization
followed by a two-phase EVP intervention. The first phase lasted 11 days
after which electrode polarity was reversed for the second phase (6.5 days)
totaling 17.5 days of EVP reinforcement. Post-EVP results revealed significant improvements: at depths of 20 cm
60 cm
and 100 cm
soil water content decreased by 4.2%
4.84%
and 2.34%
respectively
while vane shear strength increased by 32%
75%
and 61.1%. The test results indicate that superimposing the electro-osmosis method during the later stage of vacuum preloading can achieve a significant improvement in vane shear strength (with a water content reduction of less than 5%). Particularly for deep soil layers with low initial strength that are difficult to reinforce solely by vacuum preloading